Welcome to Würth Industry For trade customers only

Flachdach-Fix flat roof adhesive

Flat roof adhesive, flat roof fix
FLROOFADH-1C-PU-800ML

Art.-no. 0838892401
EAN 4050642384491
Prices for customers after login

Show availability in Würth trade store
Exclusively for trade customers

Register now and access more than 125,000 products

Wind suction-resistant bonding of heat insulation materials on flat roofs.

Tested product characteristics


Resistant to winds in accordance with EN16002, test reports I.F.I., Aachen



No mechanical application required


Reduces workload by up to 30 %. Hardens within just 60 to 120 minutes depending on the weather, meaning that subsequent work can be carried out sooner.



High degree of initial adhesion, even at low temperatures


Does not flow, but immediately forms a stable and adhesive bead. Can be applied at temperatures of +5 °C (temperature of the can must be at least +5 °C).



Long-lasting


  • Number of adhesive strands up to 25 m building height according to ZVDH (German Central Association of the Roofing Trade) procedure

  • GISCODE PU80
Notice

Adheres to all standard construction substrates such as sanded/slated bituminous membranes, expandable polystyrene and polyurethane hard foam, corrosion-protected steel sheets, fibre cement, aerated concrete, chipboard, hard PVC, stone, plaster, wood, bitumen-latex thick coatings and emulsion paints.


Please ensure that the curing times are observed to allow the propellant gases sufficient time to escape from the structure. Follow the information provided by the insulation panel manufacturer.

The usage instructions are recommendations based on the tests we have conducted and are based on our experience; carry out your own tests before each application. We do not assume any liability for a specific application result due to the large number of applications and storage and processing conditions. Insofar as our free customer service provides technical information or acts as an advisory service, no responsibility is assumed by this service except where the advice or information given falls within the scope of our specified, contractually agreed service or the advisor was acting deliberately. We guarantee consistent quality of our products. We reserve the right to make technical changes and further develop products.

Product information

Datasheets(X)

Safety data sheet

Certificates/ Documents

 | 

 | 

Application area

For clean, economical and permanently secure bonding of heat insulation panels in flat roofs and inclined roofs, as well as filling cavities between individual heat insulation elements. Particularly for uneven substrates in renovations, the insulation adhesive immediately levels any unevenness due to its direct foam structure.

Instructions

For bonding heat insulation panels based on polystyrene (EPS + extruded polystyrene), PIR/PUR hard foam and mineral wool on flat roofs. Four beads, each with a minimum diameter of 30 mm, are required per m². Increase the amount of adhesive used accordingly when applied to edge/corner areas or areas exposed to increased wind suction. The hardening process is accelerated by lightly spraying the adhesive bead with water. Then press on the insulation panel within approx. 8 minutes (depending on the temperature and air humidity).

Chemical basis

Polyurethane

Colour

Orange

Density

25 g/cm³

Yield (volume) approx.

40 l

Min. skin-formation time

8 min

Conditions for skin-formation time

at 20°C and 65% relative humidity

Can be cut after

50 min

Conditions for ability to cut

at 20°C and 60% relative humidity

Full resilience

12 h

Conditions for full resilience

at 20°C and 65% relative humidity

Min. surface processing temperature

-5 °C

Max. surface processing temperature

35 °C

Min. processing temperature for can

+5 °C

Max. processing temperature for can

25 °C

Min./max. temperature resistance

-40 to 90 °C

Building material class

B1 - Of low flammability

Building material class conditions

in accordance with DIN 4102

Heat conductance λ

0.035 W/(m*K)

Heat conductance λ conditions

in accordance with DIN 52612

Min. tensile strength

0.19 N/mm²

Conditions for tensile strength

in accordance with DIN EN 1607

Max. combined tension and shear resistance

0.489 N/mm²

Conditions for combined tension and shear resistance

in accordance with EN 12090

Solvent-free

Yes

Silicone-free

Yes

Contents

800 ml

Container

Can

Shelf life from production

12 Month

Conditions to maintain shelf life from production

at 23°C and 50% relative humidity

Roof area height (m) Indoors Inner area Outer area Corner area
Number of adhesive strands per m²
Wind zone 1 - all terrain categories
Up to 20 m 3 3 4 5
> 20 m Individual proof* Individual proof* Individual proof* Individual proof*
Wind zone 2 - terrain category 2 to 4
Up to 12 m 3 3 4 5
> 12 to 20 m 3 3 5 6
> 20 m Individual proof* Individual proof* Individual proof* Individual proof*
Wind zone 3 - terrain category 2 to 4
Up to 12 m 3 3 5 6
> 12 to 20 m 3 4 6 7
> 20 m Individual proof* Individual proof* Individual proof* Individual proof*
* Roof surfaces in wind zone 4 or terrain category 1 in wind zones 2 + 3 and buildings where high internal pressure is to be expected always require individual property-related proof in accordance with DIN 1055-Part 4.

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information